… IMRT treatments of sinus region tumors: comparison of Monte Carlo calculations with treatment planning system calculations and ion chamber measurements
… region calculated using the TPS, Monte Carlo. We also used patient-specific IMRT QA ion
chamber measurements to correct the absolute doses calculated using TPS and compared …
chamber measurements to correct the absolute doses calculated using TPS and compared …
… IMRT Treatments of Sinus Region Tumors: Comparison of Monte Carlo Calculations with Treatment Planning System Calculations and Ion Chamber Measurements
D Chin, L Jahnke, R Cormack, R Tishler… - Medical …, 2006 - Wiley Online Library
… of inhomogeneities in the sinus region is adequately accounted … ion chamber results indicate
a small systematic uncertainty in the doses calculated using the treatment planning system …
a small systematic uncertainty in the doses calculated using the treatment planning system …
Comparison of dose–volume histograms of IMRT treatment plans for ethmoid sinus cancer computed by advanced treatment planning systems including Monte Carlo
L Paelinck, B De Smedt, N Reynaert, M Coghe… - Radiotherapy and …, 2006 - Elsevier
… the critical organs calculated by the treatment planning system, … are commissioned using
the same measured set of beam … , type 60003) and an ionisation chamber (PTW-Freiburg, type …
the same measured set of beam … , type 60003) and an ionisation chamber (PTW-Freiburg, type …
Clinical implementation of full Monte Carlo dose calculation in proton beam therapy
H Paganetti, H Jiang, K Parodi… - Physics in Medicine …, 2008 - iopscience.iop.org
… to support routine treatment planning and delivery. The … mm is used while for the ionization
chamber we use 0.1 mm to … P 2001a Monte Carlo simulation of a dynamic MLC based on a …
chamber we use 0.1 mm to … P 2001a Monte Carlo simulation of a dynamic MLC based on a …
Evaluation of ion chamber dependent correction factors for ionisation chamber dosimetry in proton beams using a Monte Carlo method
H Palmans, F Verhaegen - 1995 - osti.gov
… world created by the treatment planning software. Current high-… issues regarding dynamic
conformal therapy have not been … to plan and deliver beam intensity modulated radiotherapy …
conformal therapy have not been … to plan and deliver beam intensity modulated radiotherapy …
Underdosing of the maxillary sinus for small fields used in newer radiotherapy techniques: Comparison of thermoluminescent dosimeter and Monte Carlo data
N Singh, SD Sharma, NK Painuly… - Journal of cancer …, 2018 - journals.lww.com
… fields such as intensity-modulated radiotherapy or other … is more pronounced when the
treatment planning system (TPS) … TLD measurements and MC simulations and a comparison of …
treatment planning system (TPS) … TLD measurements and MC simulations and a comparison of …
Monte Carlo evaluation of a treatment planning system for helical tomotherapy in an anthropomorphic heterogeneous phantom and for clinical treatment plans
YL Zhao, M Mackenzie, C Kirkby, BG Fallone - Medical physics, 2008 - Wiley Online Library
… Ion chamber measurements in the CIRS phantom suggested … simulation, MLC
modeling∕dynamic intensity modulation, and … Our institution's in-house IMRT protocol constraints …
modeling∕dynamic intensity modulation, and … Our institution's in-house IMRT protocol constraints …
Absolute dose calculations for Monte Carlo simulations of radiotherapy beams
IA Popescu, CP Shaw, SF Zavgorodni… - Physics in Medicine & …, 2005 - iopscience.iop.org
… , including a dynamic 7-field IMRT plan simulated on the CT … experimental measurements
using ionization chambers and … commercial IMRT Monte Carlo treatment planning system at 6 …
using ionization chambers and … commercial IMRT Monte Carlo treatment planning system at 6 …
Comparison of IMRT and VMAT plans with different energy levels using Monte-Carlo algorithm for prostate cancer
… treatment planning system with Monte Carlo algorithm. … dosimetric comparisons of VMAT
and 7-field IMRT with dynamic … the treatment plan was performed using a 2D ion chamber array …
and 7-field IMRT with dynamic … the treatment plan was performed using a 2D ion chamber array …
Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance
I Ali, S Ahmad - Medical Dosimetry, 2013 - Elsevier
… quantitatively with measurement using ionization chamber and … iPlan treatment planning
system from BrainLAB. The dose … This change was proportional to the dose and the dynamic …
system from BrainLAB. The dose … This change was proportional to the dose and the dynamic …